Release status: draft. Pilot: real Xiaomi device verification is still required.
Choose a route
Draft candidate · 32 photographs
32 shots · 21 groups
Separate proposed route; geometry checks are provisional and do not certify texture, physical occlusion or reconstruction success.
UNAPPROVED CANDIDATE. Keep both doors closed; restart under a new capture ID if door state changes. Check actual visibility and station safety in the room. Phone/FOV trial and route review remain required.
Separate proposed route; geometry checks are provisional and do not certify texture, physical occlusion or reconstruction success.
UNAPPROVED CANDIDATE. Keep both doors closed; restart under a new capture ID if door state changes. Check actual visibility and station safety in the room. Phone/FOV trial and route review remain required.
Numbered circles: stations. Arrow: planned shot. Shaded cone: usable field of view. Current, completed, skipped/gap and upcoming states also use labels and line styles.
Before starting · Xiaomi 17 Ultra
Use the 1× Leica 23 mm main camera, landscape 4:3 JPG, on one phone for the entire route.
Keep one unchanged Leica style. Turn watermark, filters, AI-scene, HDR, flash, digital zoom and Dynamic Shot off.
Keep both doors closed: entry and bathroom. If a door state must change, restart under a new capture ID.
Keep room lights and curtains stable. Stop moving screens; keep people out of the scene. Clean the lens, charge the phone, and check free space.
Hold steadily at 1.45 m ± 0.1 m. Laser focus is not LiDAR. ARCore: optional / unverified.
Station confirmation is manual and visit-local. This guide cannot verify your position, camera settings, shutter action, or existence of photographs.
Room orientation and wall review
+X runs north-to-south; +Y runs west-to-east. Map top is east, right is south, left is north. wall-00 is east/double-window; wall-01 is south; wall-05 is north; wall-02 and wall-04 face west. Both legacy-named windows (window-west and window-east) belong to wall-00. bath-door-south belongs to wall-02. wall-03 has no opening.
Wall
Role
Openings
wall-00
east double-window wall
window-west, window-east
wall-01
south long wall
none
wall-02
west-facing bathroom-door wall
bath-door-south
wall-03
connecting return
none
wall-04
west-facing entry wall
entry-door
wall-05
north measured wall
none
Coverage warnings and review
candidate-lite-32 coverage · missing
W_ADJACENT_SHARED_SPAN:S05-S06: maximum shared structural span is 0.2515 m
W_PAIRED_BEARING_GAP:CL-G1-S04: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CL-G2-S01: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CL-G2-S04: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CL-G2-S08: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CL-G3-S03: paired shot bearings exceed the provisional overlap threshold
W_SHORT_BOUNDARY_RAY:CL-030: first boundary ray is 0.9837 m
W_STATION_CLEARANCE:S02: station clearance is 0.2806 m
W_STATION_CLEARANCE:S05: station clearance is 0.2438 m
W_VERTICAL_OVERLAP:S03: pitched coverage overlaps compatible level coverage by less than 30%
W_VERTICAL_OVERLAP:S06: pitched coverage overlaps compatible level coverage by less than 30%
W_VERTICAL_OVERLAP:S07: pitched coverage overlaps compatible level coverage by less than 30%
W_VERTICAL_OVERLAP:S08: pitched coverage overlaps compatible level coverage by less than 30%
candidate-standard-64 coverage · missing
W_PAIRED_BEARING_GAP:CS-G1-S04: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G2-S01: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G2-S04: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G2-S08: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G3-S03: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G4-S01: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G4-S02: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G4-S03: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G4-S05: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G4-S06: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G6-S01: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G6-S03: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G6-S05: paired shot bearings exceed the provisional overlap threshold
W_PAIRED_BEARING_GAP:CS-G6-S06: paired shot bearings exceed the provisional overlap threshold
W_SHORT_BOUNDARY_RAY:CS-030: first boundary ray is 0.9837 m
W_SHORT_BOUNDARY_RAY:CS-040: first boundary ray is 0.9020 m
W_SHORT_BOUNDARY_RAY:CS-041: first boundary ray is 0.9958 m
W_SHORT_BOUNDARY_RAY:CS-042: first boundary ray is 0.6414 m
W_SHORT_BOUNDARY_RAY:CS-048: first boundary ray is 0.9837 m
W_SHORT_BOUNDARY_RAY:CS-056: first boundary ray is 0.9959 m
W_STATION_CLEARANCE:S02: station clearance is 0.2806 m
W_STATION_CLEARANCE:S05: station clearance is 0.2438 m
W_VERTICAL_OVERLAP:S01: pitched coverage overlaps compatible level coverage by less than 30%
W_VERTICAL_OVERLAP:S03: pitched coverage overlaps compatible level coverage by less than 30%
W_VERTICAL_OVERLAP:S06: pitched coverage overlaps compatible level coverage by less than 30%
W_VERTICAL_OVERLAP:S07: pitched coverage overlaps compatible level coverage by less than 30%
W_VERTICAL_OVERLAP:S08: pitched coverage overlaps compatible level coverage by less than 30%
Complete printable instructions — all modes
Choose one route per capture. The two ledgers are alternatives, not one combined batch.
Draft candidate · 32 photographs · 32 shots
Separate proposed route; geometry checks are provisional and do not certify texture, physical occlusion or reconstruction success.
UNAPPROVED CANDIDATE. Keep both doors closed; restart under a new capture ID if door state changes. Check actual visibility and station safety in the room. Phone/FOV trial and route review remain required.
CL-P1 · Structure
Structure
CL-G1-S01 · Structure at station 1
Structure
Station S01 · just inside the entry area · (1.3500, 1.6500) m
Frame the central approximately 1 m patch of wall-00 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-00. Aim: (2.4345, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G1-S02 · Structure at station 2
Structure
Station S02 · inner north-side route point · (2.1500, 1.5500) m
Frame the central approximately 1 m patch of wall-01 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-01. Aim: (4.9381, 2.0964) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G1-S03 · Structure at station 3
Structure
Station S03 · bathroom-door/closet approach · (3.1000, 1.4500) m
Frame the central approximately 1 m patch of wall-02 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-02. Aim: (3.6020, 0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G1-S04 · Structure at station 4
Structure
Station S04 · far side beside the bed zone · (3.6500, 1.8000) m
Frame the central approximately 1 m patch of wall-00 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-00. Aim: (2.5085, 4.2266) m.
Frame the central approximately 1 m patch of wall-01 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-01. Aim: (4.9381, 2.0741) m.
Frame the central approximately 1 m patch of wall-03 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-03. Aim: (2.3714, 0.7276) m.
Frame the central approximately 1 m patch of wall-04 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-04. Aim: (1.2825, 1.2694) m.
Frame the central approximately 1 m patch of wall-05 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-05. Aim: (0.0000, 2.7316) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G1-S05 · Structure at station 5
Structure
Station S05 · central crossing point · (2.5500, 2.1000) m
Frame the central approximately 1 m patch of wall-03 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-03. Aim: (2.3714, 0.8025) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G1-S06 · Structure at station 6
Structure
Station S06 · window side near the bed · (2.2000, 2.8000) m
Frame the central approximately 1 m patch of wall-04 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-04. Aim: (1.2571, 1.2694) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G1-S07 · Structure at station 7
Structure
Station S07 · window side near the desk · (1.5500, 2.7500) m
Frame the central approximately 1 m patch of wall-02 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-02. Aim: (3.6114, 0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G1-S08 · Structure at station 8
Structure
Station S08 · desk/entry-side return point · (1.1000, 2.1000) m
Frame the central approximately 1 m patch of wall-05 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-05. Aim: (0.0000, 2.6591) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-P2 · Measured anchors
Measured anchors
CL-G2-S01 · Measured anchors at station 1
Measured anchors
Station S01 · just inside the entry area · (1.3500, 1.6500) m
Frame window-west: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: window-west. Aim: (1.4207, 4.2266) m.
Frame bed-full: keep the full top outline (all four corners) visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: bed-full. Aim: (4.9381, 3.9360) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G2-S02 · Measured anchors at station 2
Measured anchors
Station S02 · inner north-side route point · (2.1500, 1.5500) m
Frame window-east: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: window-east. Aim: (3.1364, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G2-S03 · Measured anchors at station 3
Measured anchors
Station S03 · bathroom-door/closet approach · (3.1000, 1.4500) m
Frame entry-door: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: entry-door. Aim: (2.0697, 1.2694) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G2-S04 · Measured anchors at station 4
Measured anchors
Station S04 · far side beside the bed zone · (3.6500, 1.8000) m
Frame window-west: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: window-west. Aim: (1.5061, 4.2266) m.
Frame window-east: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: window-east. Aim: (3.2139, 4.2266) m.
Frame bath-door-south: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: bath-door-south. Aim: (3.2386, 0.0000) m.
Frame desk: keep the full top outline (all four corners) visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: desk. Aim: (0.0000, 3.7994) m.
Frame closet: keep both ends of the measured depth visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: closet. Aim: (4.9381, 1.4281) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G2-S05 · Measured anchors at station 5
Measured anchors
Station S05 · central crossing point · (2.5500, 2.1000) m
Frame bath-door-south: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: bath-door-south. Aim: (3.1864, -0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G2-S06 · Measured anchors at station 6
Measured anchors
Station S06 · window side near the bed · (2.2000, 2.8000) m
Frame desk: keep the full top outline (all four corners) visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: desk. Aim: (0.0000, 3.7659) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G2-S07 · Measured anchors at station 7
Measured anchors
Station S07 · window side near the desk · (1.5500, 2.7500) m
Frame closet: keep both ends of the measured depth visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: closet. Aim: (4.9381, 1.4124) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G2-S08 · Measured anchors at station 8
Measured anchors
Station S08 · desk/entry-side return point · (1.1000, 2.1000) m
Frame entry-door: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: entry-door. Aim: (1.7366, 1.2694) m.
Frame bed-full: keep the full top outline (all four corners) visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: bed-full. Aim: (4.9381, 3.7304) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-P3 · Floor seams
Floor seams
CL-G3-S02 · Floor seams at station 2
Floor seams
Station S02 · inner north-side route point · (2.1500, 1.5500) m
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-00; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-00. Aim: (2.4584, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G3-S03 · Floor seams at station 3
Floor seams
Station S03 · bathroom-door/closet approach · (3.1000, 1.4500) m
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-01; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-01. Aim: (4.9381, 2.0723) m.
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-03; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-03. Aim: (2.3714, 0.7891) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G3-S05 · Floor seams at station 5
Floor seams
Station S05 · central crossing point · (2.5500, 2.1000) m
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-02; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-02. Aim: (3.6073, 0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G3-S06 · Floor seams at station 6
Floor seams
Station S06 · window side near the bed · (2.2000, 2.8000) m
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-04; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-04. Aim: (1.2571, 1.2694) m.
Next: Move only after recording this group; reconfirm after changing station.
CL-G3-S07 · Floor seams at station 7
Floor seams
Station S07 · window side near the desk · (1.5500, 2.7500) m
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-05; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-05. Aim: (0.0000, 2.7482) m.
Next: Move only after recording this group; reconfirm after changing station.
Draft candidate · 64 photographs · 64 shots
Separate proposed route; geometry checks are provisional and do not certify texture, physical occlusion or reconstruction success.
UNAPPROVED CANDIDATE. Keep both doors closed; restart under a new capture ID if door state changes. Check actual visibility and station safety in the room. Phone/FOV trial and route review remain required.
CS-P1 · Structure
Structure
CS-G1-S01 · Structure at station 1
Structure
Station S01 · just inside the entry area · (1.3500, 1.6500) m
Frame the central approximately 1 m patch of wall-00 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-00. Aim: (2.4345, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G1-S02 · Structure at station 2
Structure
Station S02 · inner north-side route point · (2.1500, 1.5500) m
Frame the central approximately 1 m patch of wall-01 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-01. Aim: (4.9381, 2.0964) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G1-S03 · Structure at station 3
Structure
Station S03 · bathroom-door/closet approach · (3.1000, 1.4500) m
Frame the central approximately 1 m patch of wall-02 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-02. Aim: (3.6020, 0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G1-S04 · Structure at station 4
Structure
Station S04 · far side beside the bed zone · (3.6500, 1.8000) m
Frame the central approximately 1 m patch of wall-00 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-00. Aim: (2.5085, 4.2266) m.
Frame the central approximately 1 m patch of wall-01 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-01. Aim: (4.9381, 2.0741) m.
Frame the central approximately 1 m patch of wall-03 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-03. Aim: (2.3714, 0.7276) m.
Frame the central approximately 1 m patch of wall-04 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-04. Aim: (1.2825, 1.2694) m.
Frame the central approximately 1 m patch of wall-05 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-05. Aim: (0.0000, 2.7316) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G1-S05 · Structure at station 5
Structure
Station S05 · central crossing point · (2.5500, 2.1000) m
Frame the central approximately 1 m patch of wall-03 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-03. Aim: (2.3714, 0.8025) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G1-S06 · Structure at station 6
Structure
Station S06 · window side near the bed · (2.2000, 2.8000) m
Frame the central approximately 1 m patch of wall-04 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-04. Aim: (1.2571, 1.2694) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G1-S07 · Structure at station 7
Structure
Station S07 · window side near the desk · (1.5500, 2.7500) m
Frame the central approximately 1 m patch of wall-02 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-02. Aim: (3.6114, 0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G1-S08 · Structure at station 8
Structure
Station S08 · desk/entry-side return point · (1.1000, 2.1000) m
Frame the central approximately 1 m patch of wall-05 at lens height, retaining texture and local wall context. Do not try to fit the entire wall.
Targets: wall-05. Aim: (0.0000, 2.6591) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-P2 · Measured anchors
Measured anchors
CS-G2-S01 · Measured anchors at station 1
Measured anchors
Station S01 · just inside the entry area · (1.3500, 1.6500) m
Frame window-west: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: window-west. Aim: (1.4207, 4.2266) m.
Frame bed-full: keep the full top outline (all four corners) visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: bed-full. Aim: (4.9381, 3.9360) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G2-S02 · Measured anchors at station 2
Measured anchors
Station S02 · inner north-side route point · (2.1500, 1.5500) m
Frame window-east: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: window-east. Aim: (3.1364, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G2-S03 · Measured anchors at station 3
Measured anchors
Station S03 · bathroom-door/closet approach · (3.1000, 1.4500) m
Frame entry-door: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: entry-door. Aim: (2.0697, 1.2694) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G2-S04 · Measured anchors at station 4
Measured anchors
Station S04 · far side beside the bed zone · (3.6500, 1.8000) m
Frame window-west: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: window-west. Aim: (1.5061, 4.2266) m.
Frame window-east: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: window-east. Aim: (3.2139, 4.2266) m.
Frame bath-door-south: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: bath-door-south. Aim: (3.2386, 0.0000) m.
Frame desk: keep the full top outline (all four corners) visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: desk. Aim: (0.0000, 3.7994) m.
Frame closet: keep both ends of the measured depth visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: closet. Aim: (4.9381, 1.4281) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G2-S05 · Measured anchors at station 5
Measured anchors
Station S05 · central crossing point · (2.5500, 2.1000) m
Frame bath-door-south: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: bath-door-south. Aim: (3.1864, -0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G2-S06 · Measured anchors at station 6
Measured anchors
Station S06 · window side near the bed · (2.2000, 2.8000) m
Frame desk: keep the full top outline (all four corners) visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: desk. Aim: (0.0000, 3.7659) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G2-S07 · Measured anchors at station 7
Measured anchors
Station S07 · window side near the desk · (1.5500, 2.7500) m
Frame closet: keep both ends of the measured depth visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: closet. Aim: (4.9381, 1.4124) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G2-S08 · Measured anchors at station 8
Measured anchors
Station S08 · desk/entry-side return point · (1.1000, 2.1000) m
Frame entry-door: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: entry-door. Aim: (1.7366, 1.2694) m.
Frame bed-full: keep the full top outline (all four corners) visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed.
Targets: bed-full. Aim: (4.9381, 3.7304) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-P3 · Floor seams
Floor seams
CS-G3-S02 · Floor seams at station 2
Floor seams
Station S02 · inner north-side route point · (2.1500, 1.5500) m
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-00; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-00. Aim: (2.4584, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G3-S03 · Floor seams at station 3
Floor seams
Station S03 · bathroom-door/closet approach · (3.1000, 1.4500) m
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-01; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-01. Aim: (4.9381, 2.0723) m.
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-03; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-03. Aim: (2.3714, 0.7891) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G3-S05 · Floor seams at station 5
Floor seams
Station S05 · central crossing point · (2.5500, 2.1000) m
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-02; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-02. Aim: (3.6073, 0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G3-S06 · Floor seams at station 6
Floor seams
Station S06 · window side near the bed · (2.2000, 2.8000) m
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-04; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-04. Aim: (1.2571, 1.2694) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G3-S07 · Floor seams at station 7
Floor seams
Station S07 · window side near the desk · (1.5500, 2.7500) m
Tilt down to include a continuous approximately 1 m floor-to-wall seam on wall-05; keep visible floor texture around it. Record a skip if furniture hides the seam.
Targets: wall-05. Aim: (0.0000, 2.7482) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-P4 · Additional wall patches
Additional wall patches
CS-G4-S01 · Additional wall patches at station 1
Additional wall patches
Station S01 · just inside the entry area · (1.3500, 1.6500) m
Frame the local wall-00 patch centered 25% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-00. Aim: (1.2387, 4.2266) m.
Frame the local wall-04 patch centered 75% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-04. Aim: (0.8337, 1.2694) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G4-S02 · Additional wall patches at station 2
Additional wall patches
Station S02 · inner north-side route point · (2.1500, 1.5500) m
Frame the local wall-00 patch centered 75% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-00. Aim: (3.6638, 4.2266) m.
Frame the local wall-05 patch centered 25% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-05. Aim: (0.0000, 1.9861) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G4-S03 · Additional wall patches at station 3
Additional wall patches
Station S03 · bathroom-door/closet approach · (3.1000, 1.4500) m
Frame the local wall-02 patch centered 75% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-02. Aim: (3.0223, 0.0000) m.
Frame the local wall-03 patch centered 75% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-03. Aim: (2.3714, 0.9183) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G4-S05 · Additional wall patches at station 5
Additional wall patches
Station S05 · central crossing point · (2.5500, 2.1000) m
Frame the local wall-01 patch centered 25% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-01. Aim: (4.9381, 3.1321) m.
Frame the local wall-03 patch centered 25% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-03. Aim: (2.3714, 0.6541) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G4-S06 · Additional wall patches at station 6
Additional wall patches
Station S06 · window side near the bed · (2.2000, 2.8000) m
Frame the local wall-01 patch centered 75% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-01. Aim: (4.9381, 1.0973) m.
Frame the local wall-05 patch centered 75% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-05. Aim: (0.0000, 3.4563) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G4-S07 · Additional wall patches at station 7
Additional wall patches
Station S07 · window side near the desk · (1.5500, 2.7500) m
Frame the local wall-02 patch centered 25% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-02. Aim: (4.2513, 0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G4-S08 · Additional wall patches at station 8
Additional wall patches
Station S08 · desk/entry-side return point · (1.1000, 2.1000) m
Frame the local wall-04 patch centered 25% along its modeled segment; retain textured context and overlap with adjacent patches.
Targets: wall-04. Aim: (1.6493, 1.2694) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-P5 · Ceiling seams
Ceiling seams
CS-G5-S01 · Ceiling seams at station 1
Ceiling seams
Station S01 · just inside the entry area · (1.3500, 1.6500) m
Tilt up toward the central ceiling-to-wall seam of wall-05. Keep a continuous seam and surrounding wall visible.
Targets: wall-05. Aim: (0.0000, 2.6618) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G5-S03 · Ceiling seams at station 3
Ceiling seams
Station S03 · bathroom-door/closet approach · (3.1000, 1.4500) m
Tilt up toward the central ceiling-to-wall seam of wall-03. Keep a continuous seam and surrounding wall visible.
Targets: wall-03. Aim: (2.3714, 0.7891) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G5-S05 · Ceiling seams at station 5
Ceiling seams
Station S05 · central crossing point · (2.5500, 2.1000) m
Tilt up toward the central ceiling-to-wall seam of wall-02. Keep a continuous seam and surrounding wall visible.
Targets: wall-02. Aim: (3.6073, 0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G5-S06 · Ceiling seams at station 6
Ceiling seams
Station S06 · window side near the bed · (2.2000, 2.8000) m
Tilt up toward the central ceiling-to-wall seam of wall-04. Keep a continuous seam and surrounding wall visible.
Targets: wall-04. Aim: (1.2571, 1.2694) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G5-S07 · Ceiling seams at station 7
Ceiling seams
Station S07 · window side near the desk · (1.5500, 2.7500) m
Tilt up toward the central ceiling-to-wall seam of wall-00. Keep a continuous seam and surrounding wall visible.
Targets: wall-00. Aim: (2.3974, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G5-S08 · Ceiling seams at station 8
Ceiling seams
Station S08 · desk/entry-side return point · (1.1000, 2.1000) m
Tilt up toward the central ceiling-to-wall seam of wall-01. Keep a continuous seam and surrounding wall visible.
Targets: wall-01. Aim: (4.9381, 2.1131) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-P6 · Additional anchors and detail
Additional anchors and detail
CS-G6-S01 · Additional anchors and detail at station 1
Additional anchors and detail
Station S01 · just inside the entry area · (1.3500, 1.6500) m
Frame desk: keep the full top outline (all four corners) visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: desk. Aim: (0.0535, 4.2266) m.
Frame closet: keep both ends of the measured depth visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: closet. Aim: (4.9381, 1.5665) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G6-S03 · Additional anchors and detail at station 3
Additional anchors and detail
Station S03 · bathroom-door/closet approach · (3.1000, 1.4500) m
Frame bath-door-south: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: bath-door-south. Aim: (3.2035, 0.0000) m.
Frame the central 60 cm square of bed-top texture. This is an additional local detail image, not a whole-bed scale measurement.
Targets: bed-full. Aim: (4.4779, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G6-S04 · Additional anchors and detail at station 4
Additional anchors and detail
Station S04 · far side beside the bed zone · (3.6500, 1.8000) m
Frame the central 60 cm square of bed-top texture. This is an additional local detail image, not a whole-bed scale measurement.
Targets: bed-full. Aim: (4.0652, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G6-S05 · Additional anchors and detail at station 5
Additional anchors and detail
Station S05 · central crossing point · (2.5500, 2.1000) m
Frame window-west: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: window-west. Aim: (1.4993, 4.2266) m.
Frame entry-door: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: entry-door. Aim: (2.0006, 1.2694) m.
Frame closet: keep both ends of the measured depth visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: closet. Aim: (4.9381, 1.4585) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G6-S06 · Additional anchors and detail at station 6
Additional anchors and detail
Station S06 · window side near the bed · (2.2000, 2.8000) m
Frame window-west: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: window-west. Aim: (1.5307, 4.2266) m.
Frame window-east: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: window-east. Aim: (3.0643, 4.2266) m.
Frame entry-door: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: entry-door. Aim: (1.9019, 1.2694) m.
Frame bath-door-south: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: bath-door-south. Aim: (3.1905, -0.0000) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G6-S07 · Additional anchors and detail at station 7
Additional anchors and detail
Station S07 · window side near the desk · (1.5500, 2.7500) m
Frame window-east: keep both ends of this opening's measured width at lens height visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: window-east. Aim: (3.0543, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
CS-G6-S08 · Additional anchors and detail at station 8
Additional anchors and detail
Station S08 · desk/entry-side return point · (1.1000, 2.1000) m
Frame desk: keep the full top outline (all four corners) visible in one photograph. This width/depth view does not require the entire opening height. Keep both doors closed. Additional independent station view.
Targets: desk. Aim: (0.0009, 4.2266) m.
Next: Move only after recording this group; reconfirm after changing station.
Finish and upload
Export progress JSON alongside all original photos in one folder or ZIP. Keep original filenames, bytes and EXIF. Do not rename, crop, compress, discard extras, or send through a recompressing message app. The export contains metadata only; this guide never reads or stores image bytes.
Completion is an operator report, not proof of shutter timing. Group order is inferred. EXIF time, subseconds and timezone guide later matching; missing EXIF, repeats, reopened shots or ambiguous matches require manual review. Unassigned images remain available.
Keep one stable address
Use current Chrome on the Xiaomi at one stable HTTPS URL, or the same Mac LAN HTTP origin for the whole capture. Keep the Mac powered, awake, lid open and server running. Open and reload the exact URL before starting. Direct file/content URLs, in-app browsers, Xiaomi Browser and message-app WebViews have unverified persistence/download. Browser storage may be cleared: export regularly and before reset.